KEMOLO Freeze Dryer FD1000 Control Flow Chart
Defrost water inlet valve -- Pa -- Pa --°C --°C --°C --°C --°C --°C --°C --°C --°C --°C --°C --°C -- °C Shelf temperature Vapor condenser chamber Supplementary liquid tank 0.2 Bar -- °C Compressor Oil separator Receiver Accumulator -- °C -- °C Blower Vapor Condenser Solenoid Valve IQF Solenoid Valve Defrost water drain valve
Vacuum level 1 -- Pa Vacuum level 2 -- Pa
Auto Control(OFF)
Stop recording
Vacuum level 1
--
Pa Vacuum level 2
--
Pa
Compressor State
ParameterValueUnit
NoAlarm ContentDateTime
No alarms recorded
Recording: 0 entries
TimeShelfCond1Prod1Prod2Prod3IQF1OilSepVac1
🌡️ Drying Parameters
🔥 Heating Parameters
💨 Vacuum Parameters
❄️ Defrost Parameters
⚙️ Compressor Parameters
🔧 System Parameters
📐 Calibration
📋 Setpoints (DB1)
Drying Parameters
StepTemperature (°C)Time (min)Vacuum (Pa)
Heating Parameters
ParameterValueUnitAction
Vacuum Parameters
ParameterValueUnit
Auto Operation Setting
Setted Value
Measure Value
The current operation is adopted the recipe number of
1
The delay start time setting of compressor
25.000
S
Delay start time setting of freezer fan
25.0
S
Freezer temperature setting
-70.0
°C
19.4
°C
The lowest temperature setting of vapor condenser
-35.0
°C
The delay start time setting of compressor
10.000
S
The delay start time setting of roots pump
25.000
S
If the vacuum level is ≤ the setted value, heating will be started automatically
90.0
Pa
39925.5
Pa
If the vacuum level is > the setted value, heating will be stopped automatically
150.0
Pa
📝 Bütün değerlere tıklayarak düzenleyebilirsin. DB23 recipe 1 bloğu. Değerler HMI'da anında yansır.
Defrost Parameters
ParameterValueUnit
Compressor Parameters
ParameterValueUnit
System Parameters
ParameterValueUnit
Calibration (DB47)
SensorOffsetUnit
Setpoints / Recipe (DB1)
ParameterValueUnitAction
Final Stage Control
ParameterValueUnit
Attention: wait for 10 minutes to restart, if the compressor failure or shutdown.
PW1
PW2
feedback
feedback
CR1
CR2
Oil inlet solenoid valve
Intercooling Solenoid Valve
Oil heating
Compressor outlet valve
-1.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 12.0 -- bar
Loading
Unloading
0%
Compressor low pressure
Dual unit full load operating pressure setting -0.2 Bar Single unit energy-saving full-load operation pressure setting -0.4 Bar Single unit energy-saving partial load pressure setting -0.6 Bar
⚙️
Compressor 1 total running time 696hours 25minutes 20 The accumulated time of this startup 0minutes The accumulated time of this shutdown 559minutes
Delay time of compressor
shutting down protection
20
🔧 🧂
⚠️ Attention: wait for 10 minutes to restart, if the compressor failure or shutdown.
Compressor 2 Status
Loading
Unloading
0%
Vacuum level 1: -- Pa
In Electric Heating Mode
Accumulated running time of vacuum 0 hour 0 minute 0
Vacuum level 1 -- Pa
🔧⏳ The maintenance period of the vacuum pump is due, please deal with it in time!
🔴 Recording
🗑️ Delete historical data
📊 Historical data convert to Excel file
⏰ Correct time
📈 Historical curve
📋 Historical data report
🌡️ Compressor parameter graph
Information
The U disk, to copy the data, must be FAT32 file format, otherwise, it cannot be read. Start record by pressing the "Recording", when production. The button will be in green.
🔍+ Zoom in
🔍- Zoom out
↺ Original
📖 Curve description
Historical data report
#DateTimeCond TShelf TProd T1Prod T2Prod T3Vac 1Vac 2
Compressor temperature historical curve
Compressor oil temperature Compressor exhaust temperature
Heating mode selection and setting
Heating mode selection
Constant heating
Heating source selection
🔥
Constant heating setting
Enter
Step heating setting
Enter
Preheat parameter setting of automatic control
Enter
Constant heating temperature setting
150.0120.090.060.030.00.0
60.0
🔴 Setted heating temperature (°C)
22.5
🟢 Current heating temperature (°C)
Help
The process of constant heating is automatically controlled. The setted temperature is on the left and current temperature is on the right. Constant heating is like a ramp and keeping heating after reached the setted temperature.

Setpoint: DB1.DBW2 · Tıklayarak düzenle.
Step heating setting
Recipe: 1 Name: dilim
StepHeating time (min)Heating temp (°C)
Current heating temperature
22.6
°C
Defrost parameter settings
Defrost Mode Selection: 🔑 💧 Water Defrost
🚿💧
Water Defrost Mode Parameters Configuration → Enter
♨️💨
Steam Defrost Mode Parameters Configuration → Enter
Defrost Control Setting
Defrost water inlet time test
Defrost water inlet time
20
Minutes
⚙️
0 Minutes 0 S
Defrost water holding time
120
Minutes
Defrost water outlet time test
Defrost water outlet time
10
Minutes
⚙️
0 Minutes 0 S
Note: The manual test function is to help you set the time for automatic water inlet and drain more accurately and conveniently. When the defrost water inlet valve is opened, the water will continue to flow until it is observed that the water is sufficient, and then manually close. And fill the accumulated time in the parameter setting as defrost water inlet time and defrost water drain time.
⚠️ Defrost time değerlerinin PLC adresleri henüz haritalanmadı (HMI internal register olabilir). Tıklayıp değiştirince şimdilik yazma gitmez — HMI'da değeri değiştirirken dashboard logunu izle, adresi bulalım.
Setting the pressure protection in the heating pipe
ParameterValueUnit
0.2
Bar
Auto-valve setting 1
Whether the sensor signal setting is detected The maximum time to detect the fully open position of the electric valve Current time after open
The electric valve will be alarmed and closed, if no sensor feedback signal is detected, after the set time is exceeded.
Auto-valve setting 2
Whether the sensor signal setting is detected The maximum time to detect the fully open position of the electric valve Current time after open
The electric valve will be alarmed and closed, if no sensor feedback signal is detected, after the set time is exceeded.
Vacuum system parameter setting
ParameterTime SettingUnitCurrent TimeUnit
Refrigeration system parameter settings
Oil temperature heating control of oil separator
Oil heating:
OFF
ParameterValueUnit
--
°C
Intercooling control parameter
Intercooler 1
--
Bar
Intercooler 2
--
Bar
ParameterValueUnit
Operation mode selection: 🔀 Auto Mode ✅ DB35.DBX0.0
Auto Operation Setting
Enter
Heating Setting
Heating Setting
Defrost Control Setting
Enter
Blower defrost time setting
Enter
Setting the pressure protection in the heating pipe
Enter
Auto-valve setting
Enter
Vacuum system parameter setting
Enter
Refrigeration system parameter settings
Enter
⚠️ Caution! Auto operation is prohibited during manual operation. Manual operation is prohibited during auto operation. But it can be transferred to manual operation, when auto operation gets stopped, all output point is stopped the same time.

📋 Proses Kayıtları

IDMakinaÜrün BaşlangıçBitişSüre NemDurumİşlem
Yükleniyor…
Proses Detayı
Yükleniyor…
Information

Compressor 1 maintenance information

Maintenance time setting
1 hour 0 min
Total running time since last maintenance
-- hours
To the next maintenance period
-- hours
Compressor 1 alarm information
Information

Compressor 2 maintenance information

Maintenance time setting
1 hour 0 min
Total running time since last maintenance
-- hours
To the next maintenance period
-- hours
Compressor 2 alarm information
Blower defrost time setting
Blower defrost time setting
30
Min
Blower defrost time
0
Min
Information

Heating information

Vacuum level 1
--
Pa
Vacuum level 2
--
Pa
Heating setpoint
--
°C
Shelf temperature
--
°C

✍️ Write Parameter

Equipment

Q0.0
Q: -- · M: --